RADIO FREQUENCY (RF) EMANATIONS TESTING FOR A SHIELDED ROOM
Agency: | DEPT OF DEFENSE |
---|---|
Level of Government: | Federal |
Category: |
|
Opps ID: | NBD00159218642679759 |
Posted Date: | May 23, 2023 |
Due Date: | Jun 22, 2023 |
Solicitation No: | FA8621-23-C-XXXX |
Source: | https://sam.gov/opp/c1cbfa29bc... |
Procurement Technical Assistance Centers (PTACs) are an official government contracting resource for small businesses. Find your local PTAC (opens in new window) for free government expertise related to contract opportunities.
- Contract Opportunity Type: Sources Sought (Original)
- All Dates/Times are: (UTC-04:00) EASTERN STANDARD TIME, NEW YORK, USA
- Original Published Date: May 23, 2023 09:14 am EDT
- Original Response Date: Jun 22, 2023 12:01 am EDT
- Inactive Policy: Manual
- Original Inactive Date: Jun 22, 2023
-
Initiative:
- None
- Original Set Aside:
- Product Service Code: C219 - ARCHITECT AND ENGINEERING- GENERAL: OTHER
-
NAICS Code:
- 541330 - Engineering Services
-
Place of Performance:
Wright Patterson AFB , OH 45433USA
The Air Force Life Cycle Management Center, Simulators Division (AFLCMC/WNS), requires Radio Frequency (RF) testing for a 100 square foot room. This testing is required to certify the room to operate without restricting the use of electronic devices within a three-meter perimeter outside of the room.
The contractor shall test and report if the current rFOIL shielding satisfies both below standards for shielding effectiveness:
- The Air Force standard for shielding effectiveness (attenuation) for shielded enclosures and global shielding is 50 dB (plus an initial 10-dB allowance for life-time degradation); and
- The standard for equipment performing an instrumented test in this environment shall be performed IAW National Security Telecommunications and Information System Security Advisory Memorandum (NSTISSAM/TEMPEST 1-93).
These standards are specified in Air Force Systems Security Instruction (AFSSI) 7702, paragraph 10.4.5.
In addition, the contractor shall:
- Hold a SECRET clearance or higher;
- Be capable of sending a visit request via Defense Information for Security System (DISS) web application;
- Acquire base access to Wright-Patterson Air Force Base, OH;
- Possess mobile calibrated testing equipment capable of measuring emanations outside of a 100 square foot area shielded room;
- Transport testing equipment with set-up and break-down.
- Be certified by the NSA TEMPEST Certification Program (TCP) to perform the Certified Test Service Program;
- Author a test plan formatted IAW paragraph 2 of the Field Test Memorandum issued by the NSA;
- After Government approval of the test plan, conduct a test IAW the above outlined requirements; and;
- Provide final report of test results.
- CP 937 656 5842 2300 D ST BLDG 32
- WRIGHT PATTERSON AFB , OH 45433-7249
- USA
- Jenifer Moore
- jenifer.moore@us.af.mil
- Dominic McClung
- dominic.mcclung@us.af.mil
- May 23, 2023 09:14 am EDTSources Sought (Original)
TRY FOR FREE
Not a USAOPPS Member Yet?
Get unlimited access to thousands of active local, state and federal government bids and awards in All 50 States.